Water Purifier Control Kit

Easily test your filters and membranes with the Water Purifier Check Kit. Improve water quality, instantly evaluate chlorine, hardness and pH levels.

  • Rapid result test format
  • Practical field-use analysis
  • Minimum 50 tests per kit
  • Suitable for water quality monitoring
Providing details like intended use, delivery location, packaging preference, and quantity will help us offer you faster and more accurate pricing.
Product Code: 265
Barcode: 8680131852659
Last update: 15 Temmuz 2026 , Çarşamba
 
 
TESTONIC WATER PURIFIER CONTROL SOLUTIONS

Water Purifier
Control Kit

Inlet filter, membrane, mineral filter and alkaline filter control

Evaluate the principal filtration stages of your household water purifier separately using four different control solutions and rapidly monitor possible changes in filter performance through colour formation.

4 Different Controls
Approximately 50 Tests
Results in 5 Minutes
No Instrument Required
Check Each Filter Separately

Evaluate the inlet, membrane, mineral and alkaline filtration stages using dedicated solutions.

Only 3 Drops

Add three drops of the appropriate test solution to a water sample collected from the relevant point.

Colour-Based Result

The developed colour provides rapid preliminary information about the operating condition of the relevant filter.

Rapid Evaluation

The basic performance of each filtration stage can be compared within a few minutes.

Why should water purifier filters be checked?

In household water purifiers, water passes through several filtration stages with different functions. Pre-filters help reduce chlorine and certain unwanted substances, while the membrane separates a significant portion of dissolved substances. Mineral and alkaline filters contribute to the final characteristics of the treated water.

Filter performance may change over time depending on service life, inlet-water quality, daily water consumption, pressure, holding time and maintenance frequency. Periodic comparison of the water from individual filter outlets may support more informed maintenance decisions than relying only on a fixed replacement schedule.

The Testonic Water Purifier Control Kit provides rapid preliminary checks of the inlet filter, membrane, mineral filter and alkaline filter stages based on colour change.

Four Basic Controls Provided by the Kit

1. INLET FILTERS

Inlet Control Solution

Used for a rapid check of the chlorine-reduction performance of the pre-filter set. Collect the sample after the inlet filter set.

If yellow colour develops: Chlorine removal may have weakened. A darker colour may indicate an increased need to inspect or replace the filters.
If no yellow colour develops: The inlet filters are considered to be maintaining their chlorine-reduction function.
2. MEMBRANE FILTER

Membrane Control Solution

Used for rapid assessment of possible changes in membrane separation performance. Collect the water sample from the membrane outlet.

Red colour: May indicate weakened membrane performance. A darker colour may indicate a more pronounced need for inspection or replacement.
Blue or green colour: The membrane is considered to be operating effectively.
3. MINERAL FILTER

Mineral Control Solution

Used for a rapid preliminary check of whether the mineral filter is contributing minerals to the final water. Collect the sample after the mineral filter.

Red colour: The mineral filter is considered to be providing a measurable mineral effect.
Green colour: The mineral-filter effect may have decreased; filter inspection or replacement may be considered.
4. ALKALINE FILTER

Alkaline Control pH Solution

Used to evaluate the general pH character of the final drinking-water outlet and the effect of the alkaline filter through colour change.

Green or blue colour: The water is considered neutral or mildly alkaline and the alkaline filter is considered to be maintaining its function.
Orange or yellow colour: The alkaline-filter effect may have decreased; inspection or replacement may be required.
Technical Information

This kit is designed for rapid and comparative assessment of the filtration stages of a water purifier. The results do not independently determine exact filter capacity, microbiological safety, all dissolved substances or the numerical rejection rate of the membrane. Uncertain results should be supported by purifier maintenance, conductivity/TDS measurement, pH measurement or an appropriate laboratory analysis.

Where Should the Samples Be Collected?

1
After the Inlet Filters

Inlet Control Solution

2
Membrane Outlet

Membrane Control Solution

3
After the Mineral Filter

Mineral Control Solution

4
Final Drinking-Water Outlet

Alkaline Control pH Solution

Do not mix samples collected from different filtration stages. Before each test, rinse the test tube thoroughly with the relevant water sample.

General Test Procedure

1

Identify the correct sampling point for the filtration stage to be checked.

2

Rinse the test tube thoroughly with the collected water sample.

3

Fill the test tube to the middle mark with the water sample.

4

Add 3 drops of the appropriate control solution.

5

Mix gently and allow the developed colour to stabilise.

6

Interpret the result according to the colour guidance for the relevant solution.

Quick Result Interpretation Table

Control stage Favourable result Result requiring inspection
Inlet filters No yellow colour develops Yellow or dark-yellow colour develops
Membrane Blue or green colour Red or dark-red colour
Mineral filter Red colour Green colour
Alkaline filter / final water Green or blue colour Orange or yellow colour

Monitor Filter Performance Comparatively

Perform the first test after installing new filters to establish a baseline. Comparing subsequent colour results with the initial results may help you recognise declining filter performance more easily.

After Filter Replacement

Record the initial colour results of the newly installed filters as a reference.

Periodic Check

Repeat the same tests regularly according to the intensity of use.

Before Maintenance

Evaluate which filtration stage may have weakened before servicing or filter replacement.

Applications

  • Household reverse-osmosis water purifiers
  • Under-counter multi-stage purification systems
  • Checks before and after filter replacement
  • Rapid preliminary assessment of membrane performance
  • Monitoring the effect of mineral and alkaline filters
  • User checks before requesting technical service

Who Is It Suitable For?

  • Consumers who want to check their household purifier
  • Water-purifier technical services
  • Filter and membrane suppliers
  • Apartment and business maintenance teams
  • Water-purification installation personnel
  • Educational and application laboratories

Technical Specifications

Product type Multi-stage water purifier control kit
Controlled stages Inlet filter, membrane, mineral filter and alkaline filter
Evaluation method Visual colour formation and comparative preliminary assessment
Sample volume Up to the middle mark of the test tube
Reagent volume 3 drops per test
Number of control solutions 4 different test solutions
Total test time Approximately 5 minutes
Approximate test capacity 50 tests
Storage temperature 8–24 °C
Intended use Rapid preliminary performance check of water-purifier filters

Package Contents

Inlet Control Solution Control of chlorine-reduction performance of the pre-filters
Membrane Control Solution Rapid preliminary check of membrane-outlet performance
Mineral Control Solution Control of the mineral filter’s effect on the water
Alkaline Control pH Solution Assessment of the general pH character of the final water
Test Tube Container for sample preparation and colour assessment
Instructions for Use Sampling, test procedure and result interpretation information

For More Reliable Results

  • Collect each sample from the correct filtration-stage outlet.
  • Rinse the test tube thoroughly with the relevant water sample before testing.
  • Adjust the sample volume to the middle mark of the test tube.
  • Use only the designated control solution for each test.
  • Do not allow the dropper tips to contact the sample or test tube.
  • Evaluate the colours against a white background in a well-lit environment.
  • Compare samples from different points under the same lighting conditions.
  • Close the solution bottles immediately after use.
  • Do not use expired solutions or solutions whose appearance has changed.
Safe Use and Cleaning
  • Do not drink the test solutions or tested water.
  • Keep the solutions out of the reach of children.
  • Dispose of the tested water into the sink.
  • Clean the test tube by rinsing it thoroughly with membrane-outlet water.
  • After use, store the kit in a cool, dry place away from direct sunlight.
 

Check the main filters of your water purifier yourself

Evaluate the inlet filter, membrane, mineral filter and alkaline-filter performance through colour change in a few simple steps, and monitor maintenance and replacement timing more effectively.

Important Information

This product is intended for rapid field checks and preliminary assessment of water-purifier filtration stages. The test result alone does not confirm drinking-water safety, microbiological safety, membrane rejection rate or compliance with all chemical parameters. In case of uncertain results, inspection by an authorised technical service and appropriate measurement methods are recommended.

Technical Documents

No technical document has been added for this product yet.
Related Posts

Related News

Technical Support and Product Consulting

You can use the form to find the most suitable chemical solution for your needs or to obtain detailed information about the technical specifications of our products.
Your requests are carefully reviewed and answered by Colin's expert team.

You can ask us about the product.

Colin Chemical Industry Inc.
We have been offering specific solutions for your scientific preferences for 26 years.

İkitelli OSB Mutsan Sanayi Sitesi M10 Blok No:3 Başakşehir İSTANBUL


© 2026 Colin Kimya San. ve Tic. A.Ş. All Rights Reserved. 18.97.9.168